Metallische Bänder
0.06mm
|
Kupferband
|
0.035mm
|
10mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
|
1mm
|
-
|
0.6mm
|
75mm
|
5m
|
Leitfähig
|
-
|
-
|
Zinn
|
-
|
+120°C
|
-
|
-30°C
|
-
|
|
0.09mm
|
Aluminiumband
|
0.05mm
|
50mm
|
50m
|
-
|
3,8 N/cm
|
Aluminiumfolie
|
-
|
-
|
+110°C
|
-
|
-20°C
|
-
|
||
0.07mm
|
Aluminiumband
|
0.03mm
|
50mm
|
45m
|
-
|
3,6 N/cm
|
Aluminiumfolie
|
-
|
-
|
+110°C
|
-
|
-20°C
|
-
|
||
0.06mm
|
Kupferband
|
0.035mm
|
19mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.065mm
|
Kupferband
|
0.035mm
|
19mm
|
33m
|
Nichtleitend
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.065mm
|
Kupferband
|
0.035mm
|
25mm
|
33m
|
Nichtleitend
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.08mm
|
Aluminiumband
|
0.04mm
|
50mm
|
45m
|
-
|
3,8 N/cm
|
Aluminiumfolie
|
-
|
-
|
+110°C
|
-
|
-20°C
|
-
|
||
0.06mm
|
Kupferband
|
0.035mm
|
25mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
-
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
-
|
||
0.09mm
|
Kupferband
|
0.04mm
|
19.1mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Zinn
|
44N/cm
|
+130°C
|
-
|
-40°C
|
1182
|
||
|
0.07mm
|
Aluminiumband
|
0.03mm
|
50mm
|
45m
|
Nichtleitend
|
3,6 N/cm
|
Acryl
|
-
|
12N/cm
|
+110°C
|
-
|
-20°C
|
AT502
|
|
0.12mm
|
Aluminiumband
|
0.08mm
|
50mm
|
55m
|
Leitfähig
|
5,1 N/cm
|
Acryl
|
-
|
5.3N/cm
|
+149°C
|
-
|
-54°C
|
425
|
||
0.07mm
|
Kupferband
|
0.04mm
|
12.7mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+155°C
|
-
|
-20°C
|
1181
|
||
0.19mm
|
Aluminiumband
|
0.085mm
|
25mm
|
33m
|
Leitfähig
|
5,7 N/cm
|
Acryl
|
-
|
236N/cm
|
+316°C
|
-
|
-54°C
|
363
|
||
0.05mm
|
Klebeband
|
-
|
25mm
|
33m
|
Leitfähig
|
907 Pa
|
Acrylat
|
-
|
-
|
-
|
-
|
-40°C
|
9703
|
||
|
0.07mm
|
Kupferband
|
0.035mm
|
10mm
|
33m
|
Nichtleitend
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
Ohne
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
AT525
|
|
|
|
0.06mm
|
Kupferband
|
0.035mm
|
25mm
|
33m
|
Leitfähig
|
4,5 N/cm
|
Wärmeverhärtetes Acryl
|
Ohne
|
40N/cm
|
+155°C
|
BS EN 60454 Teil 2
|
-20°C
|
AT526
|
0.07mm
|
Kupferband
|
0.04mm
|
12mm
|
33m
|
Nichtleitend
|
4,4 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+130°C
|
-
|
-40°C
|
1194
|
||
0.07mm
|
Kupferband
|
0.04mm
|
9.5mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+155°C
|
-
|
-20°C
|
1181
|
||
0.10mm
|
Kupferband
|
0.04mm
|
6mm
|
16m
|
Leitfähig
|
3,8 N/cm
|
Acryl
|
Ohne
|
44N/cm
|
+130°C
|
-
|
-40°C
|
1245
|